Thông số kỹ thuật Đầu Đo Điện Áp Cao DC Hioki P2000:
Đầu Đo Điện Áp Cao DC Hioki P2000 Phụ kiện cho máy: DT4261, CM4141-50, CM4371-50, CM4373-50, CM4375-50, DT4281, DT4282, DT4252, DT4253, DT4255, DT4256
Basic specifications
Accuracy guaranteed: 1 year, Accuracy guarantee period after adjustment made by Hioki: 1 year
Maximum input voltage (*1) | DC 2000 V |
---|---|
Maximum rated line-to-ground voltage | 1000 V (Measurement Category IV), Anticipated transient overvoltage 12000 V 2000 V (Measurement Category III), Anticipated transient overvoltage 15000 V |
Input resistance | 20 MΩ ±5.0% (between INPUT H and INPUT L, when OUTPUT terminal is open) |
Overload protection | 2200 V DC/2200 V AC (applied for 1 minute) (between INPUT H and INPUT L) 600 V DC/600 V AC (applied for 1 minute) (between OUTPUT H and OUTPUT L) |
OUTPUT terminal | 4 mm banana terminal |
Operating temperature and humidity range | Temperature: -25°C to 65°C (-13°F to 149°F)Humidity: −25°C to 40°C (−13°F to 104°F): 80% RH or less (non-condensing) 40°C to 65°C (104°F to 149°F): Linearly reduces from 80% RH or less at 40°C (104°F) to 25% RH or less at 65°C (149°F) (non-condensing) |
Storage temperature and humidity range | -30°C to 70°C (-22°F to 158°F) 90% RH or less (non-condensing) |
Standards | EN 61010 |
Included accessories P2000 | Connection Cable Set L4943 ×1, Strap with buckle ×2, Strap ×1, Carrying Case C0205 ×1, Instruction Manual ×1, Operating Precautions ×1 |
DC HIGH VOLTAGE PROBE P2000
Safe Inspection of Solar Installations with High Voltage
Basic specifications
Accuracy guaranteed: 1 year
Maximum input voltage (*1) | DC 2000 V |
---|---|
Maximum rated line-to-ground voltage | 1000 V (Measurement Category IV), Anticipated transient overvoltage 12000 V 2000 V (Measurement Category III), Anticipated transient overvoltage 15000 V |
Input resistance | 20 MΩ ±5.0% (between INPUT H and INPUT L, when OUTPUT terminal is open) |
Overload protection | 2200 V DC/2200 V AC (applied for 1 minute) (between INPUT H and INPUT L) 600 V DC/600 V AC (applied for 1 minute) (between OUTPUT H and OUTPUT L) |
OUTPUT terminal | 4 mm banana terminal |
Operating temperature and humidity range | Temperature: -25°C to 65°C (-13°F to 149°F) Humidity: −25°C to 40°C (−13°F to 104°F): 80% RH or less (non-condensing) 40°C to 65°C (104°F to 149°F): Linearly reduces from 80% RH or less at 40°C (104°F) to 25% RH or less at 65°C (149°F) (non-condensing) |
Storage temperature and humidity range | -30°C to 70°C (-22°F to 158°F) 90% RH or less (non-condensing) |
Standards | EN 61010 |
Included accessories | Connection Cable Set L4943 ×1, Strap with buckle ×2, Strap ×1, Carrying Case C0205 ×1, Instruction Manual ×1, Operating Precautions ×1 |
Accuracy table for compatible instruments
Model | Combined accuracy |
---|---|
DT4261 | Range 600.0 V: Combined accuracy ±0.5% rdg ±0.2 V Range 2000 V: Combined accuracy ±0.5% rdg ±5 V |
CM4141-50 CM4371-50 CM4373-50 CM4375-50 | Range 600.0 V: Combined accuracy ±1.0% rdg ±0.3 V Range 2000 V: Combined accuracy ±1.0% rdg ±3 V |
DT4281 DT4282 | Range 60.000 V: Combined accuracy ±0.8% rdg ±0.002 V (output rate 1/10) Range 600.00 V: Combined accuracy ±0.8% rdg ±0.02 V (output rate 1/10) |
DT4252 DT4253 | Range 60.00 V: Combined accuracy ±1.2% rdg ±0.05 V (output rate 1/10) Range 600.0 V: Combined accuracy ±1.2% rdg ±0.5 V (output rate 1/10) |
DT4255 DT4256 | Range 60.00 V: Combined accuracy ±1.2% rdg ±0.03 V (output rate 1/10) Range 600.0 V: Combined accuracy ±1.2% rdg ±0.3 V (output rate 1/10) |